ORIGINAL ARTICLE
System-Level Analysis of a DCMD and PEMWE Integrated System for
Hydrogen and Water Cogeneration
More details
Hide details
1
Department of Mechanical Engineering, King Fahd University of Petroleum & Minerals
Submission date: 2026-04-24
Final revision date: 2026-05-17
Acceptance date: 2026-08-24
Publication date: 2026-11-16
Corresponding author
Atia Esmaeil Khalifa
Department of Mechanical Engineering, King Fahd University of Petroleum & Minerals
Journal of Undergraduate Research International 2026;2(3B):163-172
KEYWORDS
TOPICS
ABSTRACT
The integration of desalination and hydrogen production offers a promising pathway to simultaneously address water scarcity
and clean energy demands. This study evaluated the feasibility and performance of coupled direct contact membrane distillation
(DCMD) and proton exchange membrane water electrolyzer (PEMWE) systems for water–hydrogen cogeneration. A validated
steady-state model was developed, incorporating coupled heat and mass transfer in DCMD and electrochemical, thermal, and
hydrogen production models for PEMWE. A parametric analysis was conducted under two operational scenarios: (i) full coupling
with zero net water output, and (ii) cogeneration of freshwater and hydrogen. The results indicate that system operation is
constrained by the balance between DCMD production and PEMWE consumption, yielding a maximum current density of 2.29
A/cm² for a 50 cm² (1–2 kW) electrolyzer supported by a 200 cm² DCMD membrane. The net water production decreased from
approximately 0.70 kg/h at zero current density to zero at this limit. The system efficiency decreased with increasing current density
owing to rising activation and ohmic losses, as well as higher cooling requirements. By contrast, increasing stack temperature from
50 to 80 °C reduced cell voltage and improved overall efficiency, while lowering cooling demand. The feed temperature strongly
enhanced the DCMD productivity, enabling higher feasible operating current densities. In the cogeneration mode, increasing the
membrane area to 0.5 m² enabled simultaneous operation, with more than 95% of the produced water remaining available as useful
output. These findings provide design insights for the development of water-efficient green hydrogen systems, particularly for
deployment in water-limited regions