ORIGINAL ARTICLE
Effect of a Microbial Surfactant on the Surface Tension and Contact
Angle in Hydrogen Geostorage
More details
Hide details
Submission date: 2026-04-23
Final revision date: 2026-05-16
Acceptance date: 2026-08-23
Publication date: 2026-11-22
Journal of Undergraduate Research International 2026;2(3C):198-212
KEYWORDS
TOPICS
ABSTRACT
Understanding gas/brine interfacial tension (IFT) and rock wettability is essential for evaluating underground H₂ storage, particularly
when a native or cushion gas is present and when the aqueous phase is modified to alter its interfacial behavior. This study
investigates binary H₂/CH₄ mixtures at various pressures and temperatures to assess the effects of microbial-surfactant addition
on IFT and static contact angles (CAs). CAs were measured on quartz (reservoir-side analogue) and Wolfcamp shale (seal-side
analogue) using brine (Fluid 1, quartz and shale) and rhamnolipid-containing brine (Fluid 2; quartz only). Gas/brine IFT was
measured for both fluids, and the resulting IFT and CA data were used to estimate static column-height support. All untreated
systems exhibited water-wet to weakly water-wet characteristics (CA = 28°–55°). Thus, the wettability measurements primarily
quantify changes in CA caused by gas composition and rhamnolipid addition and demonstrate how these changes interact with IFT
in column-height calculations. Rhamnolipid addition consistently reduced IFT, but did not guarantee improved column-height
support because the reduction in IFT often outweighed the beneficial reduction in CA. On quartz, Fluid 2 yielded lower estimated
column heights than Fluid 1, indicating that surfactant-induced IFT reduction dominated the capillary response. Wolfcamp shale
provided substantially higher capillary support than quartz, confirming its role as a more relevant seal-side basis for structural trapping
assessment. These findings demonstrate that biosurfactant modification does not automatically enhance the static storage
capacity and that reservoir- and seal-side substrates cannot be considered interchangeable in H₂ storage evaluations.