Influence of wind direction and velocity on the work parameters of the S-160 gravity chimney cap
More details
Hide details
Publication date: 2021-02-12
Zeszyty Naukowe Politechniki Częstochowskiej seria Budownictwo 2020;26(1):24-30
KEYWORDS
ABSTRACT
The presented study contains the test results on the operating parameters of the S-160 chimney cap, another
construction from among those already tested. The measurements were carried out for the airflow in the
horizontal plane. The following physical parameters were changed: airflow speed within the tested chimney
cap and degree of leakage in the room model. The chimney cap drawing schemas, the range of the tests
and schema of the test stand are presented. The research methodology is described. Research results are
presented in the form of charts and summarized with conclusions.