ORIGINAL ARTICLE
Thermally Driven Closed-air Open-water HDH System Integrated
with Ejector Cooling System
More details
Hide details
1
Department of Mechanical Engineering, King Fahd University of Petroleum & Minerals, Saudi Arabia
Submission date: 2026-04-19
Final revision date: 2026-05-03
Acceptance date: 2026-08-23
Publication date: 2026-11-22
Corresponding author
Obaidallah Munteshari
Department of Mechanical Engineering, King Fahd University of Petroleum & Minerals, KFUPM, Dhahran, Saudi Arabia
Journal of Undergraduate Research International 2026;2(3C):130-141
KEYWORDS
TOPICS
ABSTRACT
Conventional closed-air open-water (CAOW) humidification–dehumidification (HDH) desalination systems are attractive for
small-scale freshwater production using low-grade thermal energy. However, their low thermal efficiency increases the required
external heat input, limiting their application. This is mainly associated with insufficient internal heat recovery and weak thermal
coupling between heating and condensation processes. A hybrid HDH configuration that integrates an air-heated CAOW HDH
cycle with a thermally driven ejector cooling system (ECS) has been developed to improve the thermal performance of the cycle.
The novelty of this study is the dual thermal coupling strategy, which combines direct air-loop heating with feedwater precooling
within a single integrated HDH–ECS configuration. Mass and energy balance equations were formulated for every system component
and assembled into a steady-state thermodynamic model, which was implemented and solved in Engineering Equation Solver
(EES). The model was validated against published HDH data, with the predicted gained output ratio deviating by less than 1%
under the same operating conditions. The effects of mass ratio, top air temperature, and ejector operating temperatures on system
performance were investigated using parametric analyses. The integrated system enhanced the peak gained output ratio of the standalone
HDH cycle by approximately 41.8%. The maximum recovery ratio of the hybrid system reached 3.3%. Results showed that
entrainment ratio is a key thermal-improvement parameter, with evaporator and condenser temperatures exerting the strongest
influence on performance. The proposed HDH–ECS configuration can improve CAOW desalination efficiency using low-grade
thermal energy.