ORIGINAL ARTICLE
Optimizing Mineral Exploration Workflows: A Quantitative
Evaluation of the Agreement Between Handheld and Laboratory
Geochemical and Petrophysical Instruments
More details
Hide details
1
College of Petroleum Engineering & Geosciences, King Fahd University of Petroleum & Minerals, Saudi Arabia
These authors had equal contribution to this work
Submission date: 2026-04-24
Final revision date: 2026-05-04
Acceptance date: 2026-08-23
Publication date: 2026-11-22
Corresponding author
Muhammad Hammad Malik
College of Petroleum Engineering & Geosciences, King Fahd University of Petroleum & Minerals, Saudi Arabia
Journal of Undergraduate Research International 2026;2(3C):88-98
KEYWORDS
TOPICS
ABSTRACT
The criticality of portable analytical tools has gained traction with an increasing trend in mineral exploration projects globally.
Handheld instruments have become integral to the rapid and efficient collection of geochemical and petrophysical data from field
environments for such mineral exploration workflows. However, reservations regarding the results are exist. Although handheld
instruments are faster, cheaper, and denser than laboratory-based techniques, concerns remain regarding their analytical reliability.
Herein, we evaluated the concordance between several handheld and laboratory measurements by analyzing eight various homogeneous
(pure minerals) and heterogeneous rock samples. The instruments used in our study included portable X-ray fluorescence
(pXRF), laboratory-based XRF, and X-ray diffraction, portable permeability instrument TinyPerm 3, and conventional laboratory
porosity measurement methods. Several simple statistical tools were used to compare the results. Although handheld tools work
well for quick screening and spatial geochemical mapping of major minerals, they are not extremely accurate for minute details, particularly
in the case of trace elements. However, these differences between handheld and laboratory results can also arise because
of simple and common analytical issues, such as sample preparation, surface roughness, matrix effects, and detection limits. Therefore,
the use of a hybrid analytical workflow that combines portable measurements with targeted selected samples for laboratory
validation is suggested to make exploration more efficient while keeping the data reliable.