PL EN
INVESTIGATING DURABILITY TIME INTERVAL OF THREE-DIMENSIONAL STEEL FRAME WITH ANGLE CONNECTIONS UNDER ELEVATED TEMPRATURE
,
 
 
 
More details
Hide details
1
Department of Civil Engineering, K.N. Toosi University of Technology, Tehran, Iran
 
 
Publication date: 2016-03-01
 
 
Adv. Sci. Technol. Res. J. 2016; 10(29):28-40
 
KEYWORDS
ABSTRACT
During recent years, much attention has been paid to the analysis of fire effect on steel structures because of fire importance and its effect on the stability of steel structures. Considering steel sensitivity to heat and high costs of steel frames retrofitting with the help of thermal covers, accurate behavior analysis of metal frames in elevated temperatures is required in order to reduce undesirable effects of temperature increase. To do so and taking into account the high costs of lab tests and their limitations in investigation of numerous parameters during any test, finite element method is used as a powerful and valuable tool in modeling of steel frames under thermal conditions. In this study, the fire effect on steel beams is studied considering the softening of connection and decrease of materials strength. Then, structure durability in fire will be analyzed in the ANSYS software. The analyzed frame is a single span three dimensional one and different conditions including connection type, longitudinal expansion effect, thermal loading and the kind of fire will be analyzed and compared. The obtained computer results will be compared with other researches results.
 
REFERENCES (35)
1.
Wong M.B. Elastic and plastic methods for numerical modelling of steel structures subject to fire. Journal of Constructional Steel Research, 57, 2001, 1–14.
 
2.
Lawson R.M. Behaviour of steel-beam-to-column connections in fire. The Structural Engineer, 68(14), 1990, 263–271.
 
3.
European Committee for Standardization – CEN. ENV - 1993-1-2-1995, Eurocode 3: Design of Steel Structures, Part 1.2: General Rules – Structural fire design, Brussels, 1995.
 
4.
Wald F., Simões da Silva L., Moore D., Lennon T., Chladná M., Santiago A., Beneš M. and Borges L. Experimental behaviour of steel structure under natural fire. Fire Safety Journal;, 41(7), 2006, 509–522.
 
5.
Wong M.B. Szafranski M.. Elastic method for design of 3-D steelstructures subject to fire. Journal of Constructional Steel Research, 60, 2004, 1095–1108.
 
6.
Jones SW, Kirby PA, Nethercot DA. The analysis of frames with semi-rigid connections—a state-of-the-art report. Department of Civil and Structural Engineering, University of Sheffield, UK; 1981.
 
7.
Lawson RM. Behaviour of steel beam-to-column connections in fire. Struct Eng., 68(14), 1990, 263–271.
 
8.
Usmani A.S., Rotter J.M., Lamont S., Sanad A.M., Gillie M. Fundamental principles of structural behaviour under thermal effects. Fire Saf. J. 36, 2001, 721–744.
 
9.
Wang Y.C., Lennon T., Moore D.B. The behaviour of steel frames subject to fire. J. Construct. Steel Res., 35, 1995, 291–322.
 
10.
Lien K.H., Chiou Y.J., Wang R.Z., Hsiao P.A. Nonlinear behavior of steel structures considering the cooling phase of a fire. 2009.
 
11.
Saedi Daryan A., Bahrampoor H. The study of behavior of Khorjini Connections in Fire. Accepted in Fire Safety Journal.
 
12.
Saedi Daryan A., Yahyai M. Behavior of welded top-seat angle connections exposed to fire. Fire Safety Journal 44, 2009, 603–611.
 
13.
Saedi Daryan A., Yahyai M. Modeling of bolted angle connections in fire. Fire Safety Journal 44 2009, 976–988.
 
14.
Saedi Daryan A., Yahyai M. Behavior of bolted top-seat angle connections in fire. Journal of Constructional Steel Research 65, 2009, 531–541.
 
15.
British Steel, The performance of beam/column/beam connections in the BS476: art 8 fire test. Reports T/RS/1380/33/82D and T/RS/1380/34/82D, 1982.
 
16.
Leston-Jones L.C., Burgess I.W., Lennon T., Plank R.J. Elevated temperature moment-rotation tests on steelwork connections. Proc. Instn Civil Engrs, Structures & Buildings, 122, 1997, 410–419.
 
17.
Al-Jabri K.S., Lennon T., Burgess I.W. and Plank R.J. Behaviour of steel and composite beam-column connections in fire. Journal of Constructional Steel Research, 46, paper no. 180, 1998, 1–3.
 
18.
Lou G.B. and Li, G.Q. Nonlinear finite element modelling of behaviour of extended end-plate bolted moment connections in fire. Fourth International Workshop – Structures in Fire, Aveiro, Portugal, 2006, 327–349.
 
19.
Armer G.S.T. and Moore, D.B. Full-scale testing on complete multistory structures. The Structural Engineer, 72(2), 1994, 30–31.
 
20.
Rubert A., Schaumann P. Structural steel and plane frame assemblies under fire action. Fire Safety Journal, 10, 1986, 173–184.
 
21.
Cooke G.M.E. and Latham, D.J. The inherent fire resistance of a loaded steel framework. Steel Construction Today, 1, 1987, 49–58.
 
22.
Liu T.C.H., Fahad, M.K. and Davies, J.M. Experimental investigation of behavior of axial restrained steel beams in fire. Journal of Constructional Steel Research, 58, 2002, 1211–1230.
 
23.
Qian Z.H., Tan K.H. and Burgess I.W. Behaviour and mechanical model of steel beam-to-column joints at elevated temperatures. Proceedings of Fifth International Conference on Advances in Steel Structures. Singapore, 2007, 783–790.
 
24.
Quintiere J.G., Marzo M. and Becken R. A suggested cause of the fireinduced collapse of the World Trade Towers. Fire Safety Journal, 37, 2002, 707–716.
 
25.
Bravery P.N.R. Cardington Large Building Test Facility. Construction details for the first building. Building Research Establishment, Internal paper, Watford 1993, pp.158.
 
26.
Moore D.B. and Lennon T. Fire engineering design of steel structures. Progress in Structural Engineering and Materials, 1(1), 1997, 4–9.
 
27.
ISO 834. Fire resistance tests – elements of building construction. 2002.
 
28.
Wei-Yong Wang, Guo-Qiang Li, Yu-li Dongc. A practical approach for fire resistance design of extended end-plate joints. Journal of Constructional Steel Research, 64, 2008, 1456–1462.
 
29.
Wei-Yong Wang, Guo-Qiang Li. Behavior of steel columns in a fire with partial damage to fire protection. Journal of Constructional Steel Research, 65, 2009, 1392–1400.
 
30.
Bradford M.A., Luu K.T. and Heidarpour A. Numerical studies of a steel beam in a frame sub-assembly at elevated Temperatures. Construction and Maintenance of Structures - Hanoi, Vietnam, December 2007.
 
31.
Bradford M.A., Luu K.T., Heidarpour A. Generic nonlinear modelling of a steel beam in a frame sub-assembly at elevated temperatures. The International Colloquium on Stability and Ductility of Steel Structures (Edited by: D. Camo-tim, N. Silvestre, P.B. Dinis) IST Press, Lisbon 2006, 293–298.
 
32.
Sokol E., Wald F., Pultar M., Bene M. Numerical simulation of cardington fire test on structural.
 
33.
ANSYS User’s manual, version 12.
 
34.
Kirby B.R. The behavior of high-strength grade 8.8 bolts in fire. J. Constr. Steel Res. 33, 1995, 3–38.
 
35.
Saedi Daryan A. A Study on Behavior of Connections in Fire. MS thesis. K.N. Toosi University, Tehran, Iran 2006.
 